HYECO CONTROL PRODUCTS

Hy-bus dry-contact controllers

Expandable relay control with optional local feedback.

Build a relay network with a four-channel master and four- or twelve-channel expansion controllers. Add compatible DIN-rail meters for loads that need measurement and local responses.

Illustrative product rendering
Hy-bus dry-contact controllers — Illustrative product rendering

Illustrative product rendering

Capabilities

Daisy-chain expansion

Hy-bus is HyECO’s proprietary Modbus-based relay expansion connection.

Network-connected master

The master design combines relay control, dual-band Wi-Fi, Bluetooth and Ethernet. Actual interfaces depend on the selected version.

Local feedback control

Compatible meters report electrical anomalies over a local link so the controller can operate the relevant relay without internet access or a separate gateway.

Understand each role in the system

Choose controllers and components around the application, from device control to local communication.

Explore the full solution
Local detection & load response · System overview System relationships, not a wiring diagram
  1. Four-channel meter · Detection
    Local Hy-bus / Modbus reporting
  2. Compatible dry-contact controller · Local logic
    Relevant relay output · Configured response
  3. Selected load equipment

Specifications & conditions

The maximums of 232 control channels and 56 locally monitored channels apply to different configurations. Controllers and meters share a 20-device limit, including the required master. Confirm rated loads, power and contact configuration for the selected version.

Compare capacity configurations

Confirm the specific model, hardware version and installation documentation during product selection.

Plan installation and integration around the application

Applications

For equipment switching, outdoor control cabinets and installations needing selective monitoring and local responses.

Installation & version checks

Confirm contact configuration, rated loads, power and installation conditions. Dry-contact output does not mean every load can be connected directly. Hy-bus is a local expansion link, not Ethernet daisy-chaining.

Application & system integration

Define relay behavior, fault responses, device groups, App/Web interfaces and backend integration per project. Agree on private deployment and interface responsibilities.

Get documentation for your product version

Tell us the product, version and application to request the available installation and integration documentation.

Request documentation

Start with your control requirements.

Tell us about your equipment, existing setup and the capabilities you want to add.

Discuss a project